ClinMax™ Human TARC/CCL17 ELISA Kit

产品评论
货号-规格
价格
Qty.
CEA-C029-96tests
¥3120.00
CEA-C029-480tests (96tests X 5)
¥ 14035.00
 ¥12632.00
Fiber-add-1piece
可选服务
询价
合计0件 产品金额¥ 0

产品信息

产品概述(Product Details)

ClinMax™ Human TARC/CCL17 ELISA Kit is a ready-to-use immunoassay kit, specifically designed to quantitate natural and recombinant human TARC/CCL17 that is present in biological samples, such as human serum, plasma, and cell culture supernatants. Our ClinMax™ ELISA Kit provides several benefits:

  1. Standards to calibrate with NIBSC/WHO standards for comparable results.
  2. Fully validation in biologic samples for detection range, sensitivity, inter- and intra-plate CV, recovery, dilution linearity, specificity, and matrix effects to ensure reliable results according to ICH M10 guideline.
  3. High-quality antibody pairs and protein standards, along with rigorous quality control, to guarantee consistent results across different batches.
  4. Simplified and straightforward protocols and ready-to-use reagents to save assay time.

应用说明(Application)

The kit is developed for quantitative detection of natural and recombinant human TARC/CCL17 in serum, plasma and cell culture supernatants. It is for research use only.

It is for research use only.

流程图(Workflow)

TARC/CCL17 Workflow

关键信息(Key Features)

AnalyteCCL17
Assay TypeSandwich-ELISA
ReactivityHuman
Sensitivity3.0 pg/mL
Range31.25pg/mL-2000 pg/mL
Assay Time1.75 hr
Sample TypeCell Culture Supernatants, Plasma, Serum.
Sample volume50 μL
Format96-wells plate breakable into 12 x 8 wells strips

Elevate your research experience with our Cytokine/Biomarker Detection Kits, where accuracy, reliability, and ease of use are converging to deliver exceptional results.

存储(Storage)

Keep the unopened kit stored at 2-8 °C. Avoid using the kit beyond its expiration date. The opened kit should be stored per components table. The shelf life is 30 days from the date of opening.

产品数据图

 

典型数据-Typical Data Please refer to DS document for the assay protocol.

TARC/CCL17 TYPICAL DATA

For each experiment, a standard curve needs to be set for each microplate, and the specific OD value may vary depending on different laboratories, testers, or equipment. The following example data is for reference only. The sample concentration was calculated based on the results of the standard curve. The minimum detectable concentration of CCL17 is less than 3 pg/mL.

 

样本值(Sample Values)

Serum – TARC/CCL17 concentrations were measured in 32 human serum samples, which were collected from healthy human subjects. The measurements of 32 samples are in the range of 1000-4000pg/mL and shown in the figure below.

TARC/CCL17 SAMPLE VALUES

基质效应(Matrix Effect)

3 types of materials were tested to observe if there were matrix effect (interference). If the concentration of hemoglobin (simulated hemolysis) is less than 3500 mg/dL(2%), the concentration of triglyceride (simulated lipid blood) is less than 3 mg/mL, testing results will not be affected.

TARC/CCL17 MATRIX EFFECT

稀释线性(Dilution Linearity)

High concentrations of human TARC/CCL17 serum samples were diluted with 1:2, 1:4, 1:8 and 1:16 ratios for gradient dilution to evaluate the linearity of the assay. In the serum samples, the average detection rate of TARC/CCL17 was 97.89%.

TARC/CCL17 DILUTION LINEARITY

批内差异(Intra-Assay Statistics)

10 replicates of each of 3 samples containing different TARC/CCL17 concentrations were tested in one assay. Acceptable criteria: CV<10%.

TARC/CCL17 INTRA-ASSAY STATISTICS

批间差异(Inter-Assay Statistics)

3 lots of samples containing different concentrations of TARC/CCL17 were tested in the independent assays. Acceptable criteria: CV<15%.

TARC/CCL17 INTER-ASSAY STATISTICS

回收率(Recovery)

TARC/CCL17 was spiked into 3 human serum samples, and then analyzed. The average recovery of TARC/CCL17 for serum samples is 93.93%.

TARC/CCL17 RECOVERY

 